Page 4 of 7
Hydrogen
Use of hydrogen is optional.
- Kermetico supplies 15-feet hose, end 9/16”-18 Female Left-hand swivel. Customer should have a regulator with this connection. Required pressure of hydrogen after regulator is 120-135 PSI (8.4-9.5 bar). Consumption of hydrogen is up to 25 SLPM.
- The system has a built-in flame arrestor and a check-valve on hydrogen hose, as well as inlet and outlet pressure transducers, used for monitoring the line and safety shutdowns. It is recommended to install the flame arrestor on hydrogen regulator at the source, too.
- Fittings: 1/4"NPT x 9/16”-18 Left thread. Hose ID 1/4”.
- Recommended Piping: Tube 1/4”OD x 0.18”ID